user.png Register      arrow.png Sign in

Thailand-icon.png United-Kingdom-icon.png

3331.png

3331

Temperature converter, loop-powered - isolated 

  • Excellent accuracy, better than 0.05% of span
  • Slimline housing of 6 mm
  • Excellent EMC performance and 50/60 Hz noise suppression
  • Selectable < 30 ms / 300 ms response time
  • Pre-calibrated temperature ranges selectable via DIP-switches

Manuals : pdf-icon.png

Data sheet : pdf-icon.png

  • Overview

  • Technical details

  •  

    Application

    • The 3331 temperature converter measures a standard Pt100, TC J and K temperature sensor, and provides an isolated passive analog current output signal.
    • High 2 port isolation provides surge suppression and protects the control system from transients and noise.
    • The 3331 can be mounted in the safe area or in Zone 2 / Division 2 areas.
    • Approved for marine applications.

    Technical characteristics

    • Flexibly loop powered by 5.5...35 VDC via connectors.
    • < 30 ms fast response time with simultaneous sensor error detection when selected.
    • Selectable 300 ms response time when signal dampening is needed.
    • Selectable internal/external CJC.
    • Excellent conversion accuracy in all available ranges, better than 0.05% of span.
    • Meeting the NAMUR NE21 recommendations, the 3331 provides top measurement performance in harsh EMC environments.
    • The device meets the NAMUR NE43 standard defining out of range and sensor error output values.
    • All terminals are protected against overvoltage and polarity error.
    • High galvanic isolation of 2.5 kVAC.
    • Excellent signal/noise ratio of > 60 dB.

    Mounting / installation / programming

    • Selectable DIP-settings for easy configuration of more than 1000 factory calibrated measurement ranges.
    • The narrow 6 mm housing allows up to 165 units to be mounted per meter of DIN rail, without any air gap between units.
    • Wide ambient temperature range of -25...+70°C.
  •  

    Environmental Conditions

    Specifications range -25°C to +70°C
    Storage temperature -40°C to +85°C
    Calibration temperature 20...28°C
    Relative humidity < 95% RH (non-cond.)
    Protection degree IP20
    Installation in Pollution degree 2 & measurement / overvoltage cat. II

    Mechanical specifications

    Dimensions (HxWxD) 113 x 6.1 x 115 mm
    Weight approx. 70 g
    DIN rail type DIN EN 60715/35 mm
    Wire size 0.13 x 2.5 mm2 / AWG 26...12 stranded wire
    Screw terminal torque 0.5 Nm
    Vibration IEC 60068-2-6 : 2007
    Vibration: 2...25 Hz ±1.6 mm
    Vibration: 25...100 Hz ±4 g

    Common specifications

    Supply voltage 5.5...35 VDC
    Voltage drop 5.5 VDC
    Isolation voltage, test 2.5 kVAC
    Isolation voltage, working 300 VAC (reinforced) / 250 VAC (Zone 2, Div. 2)
    Signal / noise ratio > 60 dB
    Signal dynamics, input 23 bit
    Signal dynamics, output 18 bit
    Response time (0...90%, 100...10%) < 30 ms / 300 ms (selectable)
    EMC immunity influence < ±0.5% of span
    Extended EMC immunity: NAMUR NE 21, A criterion, burst < ±1% of span
    Incorrect DIP-switch setting identification 3.5 mA

    Input specifications

    Temperature range, Pt100 -200...+850°C
    Accuracy, RTD: the greater of Better than 0.05% of span or 0.1°C
    Temperature coefficient, RTD: the greater of 0.02°C/°C or ≤ ±0.01%/°C
    Sensor current, RTD < 150 µA
    Sensor cable resistance, RTD < 50 Ω per wire
    Effect of sensor cable resistance (3-/4-wire), RTD < 0.002 Ω / Ω
    Sensor error detection, RTD Yes - selectable via DIP-switch
    Broken sensor detection > 800 Ω
    Shorted sensor detection < 18 Ω
    Temperature range, TC J -100...+1200°C
    Temperature range, TC K -180...+1372°C
    Accuracy, TC: the greater of Better than 0.05% of span or 0.5°C
    Temperature coefficient, TC: the greater of 0.1°C/°C or ≤ ±0.01%/°C
    Sensor cable resistance, TC < 5 kΩ per wire
    Cold junction compensation (CJC): Accuracy @ external Pt100 intput Better than ±0.15°C
    Cold junction compensation (CJC): Accuracy @ internal CJC Better than ±2.5°C
    Open Thermocouple detection Yes - selectable via DIP-switch
    Internal CJC error detection Yes
    External CJC error detection Yes - selectable via DIP-switch

    Output specifications

    Programmable current ranges 4...20 and 20...4 mA
    Range limits 3.8...20.5 mA NAMUR NE43
    Sensor error indication 3.5 mA or 23 mA / acc. to NAMUR NE43 or OFF
    Load resistance, current output ≤ (Vsupply - 5.5) / 0.023 [Ω]
    Updating time 10 ms
    Load stability, current output ≤0.01% of span / 100 Ω

    Approvals

    EMC EN 61326-1
    LVD 2006/95/EC EN 61010-1
    ATEX 2004/108/EC KEMA 10ATEX0147 X
    IECEx KEM 10.0068X
    FM 3041043-C
    DNV Marine Stand. f. Certific. No. 2.4
    GL V1-7-2
    EAC TR-CU 020/2011 EN 61326-1
    UL UL 61010-1